Uniwide XtremeServer 2544 Guía de usuario

Busca en linea o descarga Guía de usuario para Barebones Servidor Uniwide XtremeServer 2544. Uniwide XtremeServer 2544 User`s guide Manual de usuario

  • Descarga
  • Añadir a mis manuales
  • Imprimir

Indice de contenidos

Pagina 2 - Part I. User’s Guide

7Expansion Slots (Only Support Low Profile Card) Two x16 PCI-Express slot supporting full-length add-on card One x4 PCI-Express slot supporting half

Pagina 3 - Part II. Technical Guide

8BIOS AMI BIOS Support ACPI 2.0 with S0/S1/S3/S4 and S5 Support AMD PowerNow! 48-bit LBA support Support USB K/B & Mouse Serial Console Redirect

Pagina 4 - Preface

9 1.3 Mainboard Layout 1.3.1 Block Diagram

Pagina 5 - 1. Introduction

101.3.2 Mainboard Layout ① AMD® OpteronTM Socket 1207 - CPU0 ② AMD® OpteronTM Socket 1207 - CPU1 ③ AMD® OpteronTM Socke

Pagina 6 - 1.1 System Feature

112. Important Safety Only a technically qualified person shall access, integrate, configure, and service this product. To avoid personal injur

Pagina 7 - 1.1.3 Rear View

122.3 Multiple Power Sources Where a unit receives power from more than one source (for example, different voltages or frequencies or as backup pow

Pagina 8 - 1.1.5 Power LED Indication

132.7 Electrostatic Discharge (ESD) CAUTION Perform the procedures in this product guide only at an electrostatic discharge (ESD) workstation, beca

Pagina 9 - 1.2 System Specifications

143. System Installation 3.1 Preparing for Setup 3.1.1 Unpacking CAUTION In setting the product out of the box, hold it

Pagina 10

153.1.2 Packing List Unpack the package and check if all items listed below are present. If any item contained in the package is damaged or missin

Pagina 11 - Regulatory

163.1.3 Environmental Specifications Place In front of the system, minimum 25" of the space is needed for using and managing the system. In r

Pagina 12 - 1.3 Mainboard Layout

Part I. User’s Guide 1. Introduction...2 1.1 System Feat

Pagina 13 - 1.3.2 Mainboard Layout

173.1.4 Install Rail for Mounting the System on the Rack This section provides information on installing the system into a rack unit with the sli

Pagina 14 - 2. Important Safety

18Installing the Outer Rails As shown in picture below, put the rear of outer rail on right place of the rear-mounting frame, and fit it on the fron

Pagina 15 - 2.6 Fans

193.1.5 Install System at the Rack Cabinet CAUTION Remove all the cables from system before installing. CAUTION System can be heavy. To reduce the

Pagina 16 - 2.8 Cooling and Airflow

20Gold Triangle 3.2 Installing User Serviceable Component 3.2.1 CPU System mainboard accommodates Socket-F(1207 pin) AMD OpteronTM Processors at

Pagina 17 - 3. System Installation

213.2.2 Memory The system mainboard uses Dual Inline Memory Modules (DIMM). Two pair's banks are available; each bank supports one CPU with H

Pagina 18 - 3.1.2 Packing List

22Memory Installation Procedure ① Locate the DIMM modules. ② Make sure the DIMM’s pins are facing down, and check that the pin arrange

Pagina 20 - Slide Rail

243.2.3 Hard Disk Drives HDD ID Configuration HDD Type Slot #3 Slot #2 Slot #1 Slot #0SAS (SATA) ID 4 ID 3 ID 2 ID 1 NOTICE When you

Pagina 21 - Installing the Outer Rails

253.2.4 PCI Add-on Cards WARNING Please power off your power supply completely when adding removing any expansion card or other system components

Pagina 22

263.2.5 Power Module Hot Plugging WARNING If removing a power supply, release the locking latch of the power supply. ① Press the release but

Pagina 23 - 3.2.1 CPU

4.1.10 Power Menu...49 4.1.11 Exit

Pagina 24 - 3.2.2 Memory

274. BIOS and Jumper Setting 4.1 BIOS This chapter discusses the AMI BIOS Setup program built into the ROM BIOS. The Setup program allows users

Pagina 25

284.1.2 Updating BIOS Setup Creating a bootable floppy disk A. DOS environment Insert a 1.44 MB floppy disk into the drive. At the DOS prom

Pagina 26

294.1.3 Using Setup In general, you use the arrow keys to highlight items, press <Enter> to select, press <Esc> to quit. The following

Pagina 27 - 3.2.3 Hard Disk Drives

304.1.4 Main Menu This is the first screen that is displayed when you enter the BIOS Setup Utility. Each tab lined on the top of the screen repre

Pagina 28 - 3.2.4 PCI Add-on Cards

314.1.5.1 CPU Configuration Submenu In CPU configuration, you can set up CPU frequency and enable/disable the Error Reporting. GART error reportin

Pagina 29

324.1.5.2 IDE Configuration Submenu You can make the selections on IDE Configuration menu. Feature Options Description OnBoard

Pagina 30 - 4. BIOS and Jumper Setting

334.1.5.3 Floppy Configuration Submenu Feature Options Description Floppy Configuration Disabled 5 1/4” 360 KB 5 1/4” 1.2 M

Pagina 31 - 4.1.2 Updating BIOS Setup

344.1.5.4 Super IO Submenu Feature Options Description OnBoard Floppy Controller Disabled Enabled Allows BIOS to Enable or Disable F

Pagina 32 - 4.1.3 Using Setup

354.1.5.5 ACPI Configuration Submenu Feature Options Description ACPI Configuration ACPI Aware O/S Yes/No Enable: O/S supports ACP

Pagina 33 - 4.1.5 Advanced Menu

364.1.5.7 IPMI Configuration To set up the BMC LAN Configuration, you can adjust over this menu. 4.1.5.8 MPS Configuration Subm

Pagina 34

1Preface The information in this User's Guide has been carefully reviewed and is believed to be accurate. The vendor assumes no responsibili

Pagina 35

374.1.5.9 PCI Express Configuration Submenu Enable/Disable PCI Express L0 and L1 link power states. 4.1.5.10 Remote Access Confi

Pagina 36

384.1.5.11 USB Configuration Submenu Feature Options Description USB Controller Support Disabled USB 1.1 Only USB 1.1+ USB 2.0Enabl

Pagina 37

394.1.5.12 Onboard Device Configuration Submenu Feature Options Description SAS Enabled Disabled On-board SAS controller Enabled/

Pagina 38

404.1.6 PCI PnP Menu PCI PnP Menu 1 PCI PnP Menu 2

Pagina 39

41 Feature Options Description Plug & Play O/S Yes No Yes: lets the O/S configure PnP devices not required for boot if your system has a Plu

Pagina 40

424.1.7 Boot Menu Feature Options Description Quick Boot Disabled Enabled Allow BIOS to skip tests while booting Quiet Boot Disab

Pagina 41

434.1.8 Security Menu Security Menu 1: Change Supervisor Security Menu 2: Change User

Pagina 42

44 Security Menu 3: Boot Sector Feature Options Description Change Supervisor Password Install or change the password Change User

Pagina 43 - 4.1.6 PCI PnP Menu

454.1.9 Chipset Configuration Menu 4.1.9.1 NorthBridge Chipset Configuration Submenu

Pagina 44

464.1.9.2 Memory Configuration Submenu Feature Options Description Memclock Mode Auto Limit It can be set by the code using AUTO, o

Pagina 45 - 4.1.7 Boot Menu

21. Introduction The key objective for XtremeServer is to overcome the major challenges faced by developers, and system integrators alike, in depl

Pagina 46 - 4.1.8 Security Menu

474.1.9.3 ECC Configuration Submenu Feature Options Description Master ECC Enable Disabled Enabled Master ECC Enables support on al

Pagina 47

484.1.9.4 IOMMU Mode Submenu Feature Options Description IOMMU Mode AGP PresentDisabled 32MB 64MB 128MB 256MB 512MB 1GB Set GART si

Pagina 48

494.1.10 Power Menu The Power menu items allow you to change the power management settings. Select an item then press Enter to disp

Pagina 49

504.1.11 Exit Menu Feature Description Save Changes and Exit Exit system setup after saving the changes F10 key can be used for this

Pagina 50

514.2 Jumper Setting This section covers the jumper setting. Refer to the following illustration for the location of the jumpers.

Pagina 51

524.2.1 PCI-X Speed Setting(J22, J26) PCI-X speed can be selected by the switch. Please follow the below instruction.

Pagina 52 - 4.1.10 Power Menu

534.2.2 VGA Enable / Disable(J18) This header lets you set your VGA port function. You can choose enable or disable this function or not. Onboard

Pagina 53 - 4.1.11 Exit Menu

544.2.4 CPU Board Detection Enable / Disable(J2) This header lets you set your CPU board detection function. You can choose enable or disable th

Pagina 54 - 4.2 Jumper Setting

55 ID Assignment This sets up identification information of server. CPU Assignment This sets up CPU number of server. Server Type A

Pagina 55 - 2 OFF OFF ON

564.2.7 SAS Cable Connection Connector J10 is used to connect SAS cable to each SAS HDD. 4.2.8 Jumper Setting on the SAS BP Jumper J13, J14

Pagina 56 - 4.2.3 Clear CMOS Header

3d. Hard Disk Drive e. Front Bezel f. Mounting Bracket a. Slim CD-ROM Drive b. Front Panel Controls and Indicators c. FDD Ejector button 1.1

Pagina 57

575. Software & Utilities 5.1 LSILogic SAS RAID This chapter provides information how to configure and use the components of the LSI Logic

Pagina 58

58z No special OS-specific software required z High reliability and data integrity - Non-volatile write journaling - Physical disks not visible to

Pagina 59 - 4.2.7 SAS Cable Connection

59The IM feature uses the same device drivers as the standard LSI Logic Fusion-MPT based controllers, providing seamless and transparent fault toler

Pagina 60 - 5.1 LSILogic SAS RAID

605.1.2.3 IM/IME Description The LSI Logic Integrated Mirroring (IM) feature supports one or two mirrored volumes on each LSI Logic SAS controller

Pagina 61

61An IME volume can be configured with up to eight mirrored disks, or seven mirrored disks and a global hot spare. Figure shows the logical view and

Pagina 62

625.1.2.4 Integrated Mirroring Firmware This section describes features of the LSI Logic Integrated Mirroring (IM) firmware, which supports up to

Pagina 63

635.1.2.4.7 Media Verification The IM firmware supports a background media verification feature that runs at regular intervals when the IM/IME volu

Pagina 64

645.1.3 Creating Integrated Mirroring Volumes This section describes how to create Integrated Mirroring (IM) and Integrated Mirroring Enhanced (I

Pagina 65

65The following guidelines also apply when creating an IM or IME volume: z All physical disks in the volumes must be either SATA (with extended com

Pagina 66

66 ⑦ (Optional) Add a global hot spare by moving the cursor to the hot spare column and pressing the + key, . key, or space bar. ⑧ Wh

Pagina 67

41.1.3 Rear View LAN Port Function The LAN port uses a CAT 6 LAN cable for connecting the motherboard to a local area network by

Pagina 68

675.1.3.2.3 Creating s Second IM or IME Volume The LSI Logic SAS controllers allow you to configure two IM or IME volumes. If one volume is already

Pagina 69

68③ Select a disk from the list by pressing the + key, . key, or space bar. ④ After you select the global hot spare disk, press C. An error messag

Pagina 70

69Follow these steps to force the synchronization of a selected array: ① Select Synchronize Array on the Manage Array screen. ② Press Y to start t

Pagina 71

70z When you are creating an IM or IME volume, and a disk drive is set to Yes as part of the volume, the LED on the disk drive is flashing. The LED

Pagina 72

715.1.4 Integrated Striping Overview This section provides an overview of the LSI Logic Integrated Striping (IS) feature. 5.1.4.1 Introduction

Pagina 73

725.1.4.3 IS Description The IS feature writes data across multiple disks instead of onto one disk. This is accomplished by partitioning each disk’

Pagina 74

735.1.4.4 Integrated Striping Firmware This section describes features of the LSI Logic Integrated Striping (IS) firmware. 5.1.4.4.1 Host Interf

Pagina 75

745.1.5 Creating Integrated Striping Volumes This section describes how to create Integrated Striping (IS) volumes using the LSI Logic SAS BIOS C

Pagina 76

75 ③ On the Adapter Properties screen, use the arrow keys to select RAID Properties on the screen and press Enter. ④ When you are p

Pagina 77

76 The first is as follows: ① In the configuration utility, select an adapter from the Adapter List. Select the RAID Properties option. This will

Pagina 78

5 1.1.4 Inner View 1.1.5 Power LED Indication AC : Green – Normal / Yellow - Fail DC : Green – Normal / Yellow – Fa

Pagina 79

775.1.5.4.3 Deleting an Array CAUTION Before deleting an array, be sure to back up all data on the array that you want to keep. Follow these steps

Pagina 80

78④ To remove the boot designator, move the cursor down to the current boot disk and press Alt+B. This controller will no longer have a disk desig

Pagina 81

79 5.2 ServerDome Overview The ServerDome provides remote server management for the XtremeServer 1U, 2U and 3U XtremeServer. With comprehensive ma

Pagina 82 - 5.2 ServerDome Overview

801. Removing & Installing System Components 1.1 Installing the CD-ROM Drive ① Screw two brackets and the interface board to the CD-ROM.

Pagina 83 - System Components

811.2 Installing the Floppy Disk Drive ① Install the FDD with two mounting bracket. ② Install the FDD with two mounting brackets in the

Pagina 84

82 ④ Push the button and slide the front LED panel back into the system. To use the FDD, push the blue button and it will come up to the front.

Pagina 85

831.3 Installing the Hard Disk Drive ① Remove the blank disk from the disk carrier and secure HDD to the carrier with four screws. Keep the blank

Pagina 86

841.4 Removing the Power Supply Unit CAUTION In replacing the power supply, handle the unit with care because it is heavy. ① Hold the right si

Pagina 87

851.5 Replacing the Cooling Fan Unit WARNING Do not remove the fan module while operating the system. In installing the fan module, carefully se

Pagina 88

861.6 Replacing the Interface Unit 1.6.1 Backplane Unit CAUTION Before installing IFB, remove HDD carrier and locate FDD forward. ① Slide dow

Pagina 89 - 1.6.1 Backplane Unit

61.2 System Specifications Processor Four socket F (1207pin) AMD OpteronTM Processors Supports up to 4P/8C Dual-Core AMD OpteronTM 8000 Series pro

Pagina 90 - 1.6.2 SAS Cable

87④ Install the FDD and Front LED cables to the backplane. 1.6.2 SAS Cable WARNING Routing SAS cable should be prior to installing In

Pagina 91

881.7 Installing the Motherboard CAUTION In order to remove or install the motherboard, disassemble the rear cage unit from the system beforehand

Pagina 92

891.8 Installing the CPU Board CAUTION In order to install the CPU board, install base frame CPU board on the motherboard beforehand. ① Attach th

Pagina 93

90④ Press CPU board down until making a click sound after inserting HT connection board into HT slots of motherboard. ⑤ To secure CPU boar

Pagina 94

91⑦ Install AC protection cover & CPU duct. 1.9 Installing the CPU Heatsink CAUTION Make sure that thermal interface material shou

Pagina 95

921.10 Installing the Front Bezel ① Locate the front bezel on the chassis as shown below. ② Align of chassis and press right parts of b

Pagina 96 - Appendix

93Appendix A. BIOS Post Code AMIBIOS8 Check Point and Beep Code List The POST code checkpoints are the largest set of checkpoints during the BIOS p

Pagina 97

9404 Check CMOS diagnostic byte to determine if battery power is OK and CMOS checksum is OK. Verify CMOS checksum manually by reading storage area.

Pagina 98

9550 Programming the memory hole or any kind of implementation that needs an adjustment in system RAM size if needed. 52 Updates CMOS memory size f

Comentarios a estos manuales

Sin comentarios